Product Description
SPECIFICATIONS Conductor : Solid, Multistrand, Copper Material (Bare Copper,TPC,NPC,SPC)Insulation : Fiber Glass with High Temperature VarnishVoltage rating : Up to 1.1 KVOperating Temp. : 400degC FEATURESMax. Temp. Up to 400degCExcellent Abrasion ResistanceExcellent Heat ResistivityExcellent resist to Oil, moist, fluids and chemicalsExcellent Di-electric PropertiesHigh Temperature & Voltage RatingExcellent Flame Retardant AVAILABLE OPTIONS 250V/600V/1100VAs per Customer RequirementMetal Covering CONSTRUCTION DETAILS AND DIMENSIONS S.NO SIZE Number ofStrands /Dia of each Strand Dia of Conductor for Cross SectionalArea ET 250 V E 600 V EE 1000 V Max Res.OHMS/KM at 20c Cure nt Rating (amps Max Weight gm/mtr OD of insulation OD of insulation OD of insulation SWG AWG (MM) (MM) MM2 Min(mm) Max(mm) Min(mm) Max(mm) Min(mm) Max(mm) LF101 26 19/38 19/0.10 0.51 0.14 0.81 1.01 1.07 1.21 1.37 1.41 125 3 3.38 LF102 24 1/24 1/0.51 0.51 0.2 0.81 1.01 1.07 1.21 1.37 1.41 87 4 3.87 LF103 24 7/32 7/0.20 0.61 0.21 0.91 1.11 1.17 1.31 1.47 1.51 82 4 4.22 LF104 24 19/36 19/0.13 0.64 0.25 0.94 1.14 1.2 1.34 1.5 1.54 79 4 4.58 LF105 22 1/22 1/0.64 0.64 0.32 0.94 1.14 1.2 1.34 1.15 1.54 55 7.3 5.2 LF106 22 7/30 7/0.25 0.76 0.34 1.06 1.26 1.32 1.46 1.62 1.66 52 7.3 5.65 LF107 22 19/34 19/0.16 0.81 0.38 1.11 1.31 1.37 1.51 1.67 1.71 49 7.3 6.11 LF108 20 1/20 1/0.81 0.81 0.51 1.11 1.31 1.37 1.51 1.67 1.71 34 11 7.31 LF109 20 7/28 7/0.32 0.97 0.56 1.27 1.47 1.53 1.67 1.83 1.87 32 11 8.08 LF110 20 19/32 19/0.20 1.02 0.59 1.32 1.52 1.58 1.72 1.88 1.92 30 11 8.48 LF111 18 7/26 7/0.40 1.22 0.87 1.78 2.02 2.08 2.12 20 18 11.45 LF112 18 19/30 19/0.25 1.27 0.93 1.83 2.07 2.13 2.17 18 18 12.03 LF113 16 19/29 19/0.29 1.45 1.25 2.01 2.25 2.31 2.45 14 22 15.88 LF114 15 19/28 19/0.32 1.6 1.52 2.18 2.4 2.48 2.8 12 28 18.7 LF115 14 19/27 19/O.36 1.83 1.93 2.39 2.83 2.89 2.83 9 32 22.88 LF116 13 19/26 19/0.40 2 2.38 2.58 2.8 2.88 3 7 35 27.37 LF117 12 19/25 19/0.45 2.31 3.02 2.87 3.11 3.17 3.31 5 41 33.81 LF118 12 37/28 37/0.32 2.26 2.97 2.82 3.08 3.12 3.28 8 41 33.27 LF119 11 19/24 19/0.50 2.5 3.73 3.08 3.3 3.38 3.5 4 45 40.84 LF120 10 19/22 19/0.65 3.35 6.3 3.91 4.15 4.21 4.35 2 55 85.8 LF121 10 37/26 37/0.40 2.82 4.64 3.38 3.82 3.88 3.82 3 50 49.66 LK121 11 19/24 19/0.50 2.5 3.73 2.82 3 3.1 3.3 4 45 38.74 LK122 10 19/22 19/0.65 3.35 6.304 3.67 3.85 3.95 4.15 2 55 63.42 LK123 10 37/26 37/0.4 2.82 4.649 3.14 3.32 3.42 3.62 3 50 47.58
FAQs of LF-101 Lead Wire:
Q: What is the core configuration of LF-101 Lead Wire?
A: LF-101 Lead Wire has a 2-core configuration.
Q: What voltage surge ratings does LF-101 Lead Wire support?
A: LF-101 Lead Wire supports voltage surge ratings of 250V, 600V, and 1100V.
Q: What is the material used in LF-101 Lead Wire?
A: The LF-101 Lead Wire is made from copper.
Q: What is the color of the LF-101 Lead Wire?
A: The LF-101 Lead Wire is grey in color.
Q: What is the primary usage of LF-101 Lead Wire?
A: The LF-101 Lead Wire is used for electric applications.